Home > Buy Now > Other Manufacturing & Processing Machinery > After Coolers
 


Keumsung Hightech Co., Ltd.
 
icon Product List

line

icon Company Profile
icon Index
icon Bulletin Board
icon Guest Book

line



visitors: 972
 
Contact us
Keumsung Hightech Co., Ltd.
[Korea]
Address:
460-5, Galsan-ri, Wolgok-myeon Gimpo-gun Gyeonggi-do 415-870 Korea
Phone:
82-31-9892700
Contact name:
Heung-seok, Park , President
Inquire now









Keumsung Hightech Co., Ltd.
 
Product List

After Coolers

Inquire now

After Coolers

Click to enlarge image


Structure and Features

  • Coil
    Heat exchangeable coil made of coppertube and aluminum pins are apple to the article and polluted sustances are minimized to be attached to select the gaps of the fins
  • Motor(R)
    The articles need not repairing and owing to the self lubricating special motors, efficinet tolerance and durability has been achieved
  • Construction
    Owing to the power heating treatment on the film color coated steel plate. Installation outdoor is available
  • Fan(S)
    Owing to the optimally planned duminum fan, precise balance for the operation is possible with minimum vibration and roise during the operation

Remark

Inlet temperature
Max 90 ℃
Ambient temperature
Under 38℃
Design pressure
12.2kg/㎠
Model

Capacity
(N㎡/min)

Motor
Fan
DiaΦ

Remark

A
B
KW
Pole
Q`TY
GSAC-20N
2.5 3.2 0.1 4 1 300

Treatment capacity is based on the condition of 7kg/㎠ in case of the surrounding temperature of 38℃

In case of the following condition of

A: Entrance temperature 90℃

B: Entrance temperature 60℃ the capacity will be the maximum

GSAC-30N
4.0 5.1 0.1 4 1 350
GSAC-50N
7.0 8.2 0.1 4 2 350
GSAC-75N
10.0 12.5 0.2 4 2 400
GSAC-100N
14.0 17.0 0.2 6 2 450
GSAC-150N
21.0 25.0 0.4 6 2 500
GSAC-200N
28.0 32.0 0.4 6 2 500
GSAC-300N
40.0 46.0 0.4 6 2 600
GSAC-400N
52.0 60.0 0.75 6 2 650
GSAC-500N
65.0 75.0 1.5 6 2 750

Dimensions

Model

Dimension
(LxWxH)

In/out
Weight(kg)

Remark

GSAC-20N
2.5
25A
27

During and after the operation, codersed water v/v should be opeened and if automatic drainage is necessory, reter to 35 page of the company catalogue for the most appropriate application

GSAC-30N
4.0
40A
37
GSAC-50N
7.0
50A
67
GSAC-75N
10.0
65A
100
GSAC-100N
14.0
80A
125
GSAC-150N
21.0
80A
225
GSAC-200N
28.0
100A
245
GSAC-300N
40.0
100A
270
GSAC-400N
52.0
125A
320
GSAC-500N
65.0
150A
375



Inquire now